Macromatic TCF2E: Ebara Clone, Temp/Seal Leak

$258.95

  • SEAL LEAKAGE & OVER TEMPERATURE RELAY
  • OVER TEMPERATURE & SEAL LEAKAGE | AUTO & MANUAL RESET
  • 120V AC
  • 7A SPDT & SPNC

Description

Two wires from the Over Temp/Seal Leakage relay are connected to a N.C. thermal switch in the windings of the pump motor to monitor for overheating. A low-voltage DC signal is applied to check the status of the thermal switch. Two additional wires are connected to a N.C. float switch in the Leakage Sensor. A separate low-voltage DC signal is applied to check the status of the Leakage Sensor. These products have isolated output contact relays, one for over temperature and one for seal leakage.

With input voltage applied, normal temperature condition (thermal switch closed) and no seal leakage (Leakage Sensor contact closed), both the over temperature relay and the seal leakage relay are energized. The TEMP & SEAL LEDs are both Green, indicating normal conditions and input voltage applied.

When the motor temperature rises and the N.C. thermal switch opens, the over temperature relay is de-energized, opening a contact that had been closed and turning off the pump contactor. The TEMP LED turns Red. If the over temperature condition is cleared, the unit will reset based on the setting of the Over Temp switch. In the AUTO mode, the unit will reset automatically. In the MANUAL mode, the Over Temp Reset button must be pushed to clear the alarm and reset the relay.

If the seal starts to leak, contaminating fluid enters the pump motor cavity. The contact in the Leakage Sensor will open and the seal leakage relay is de-energized, reclosing a contact that was opened and providing an alarm indication of a leaking seal. The SEAL LED turns Red.

TCF-E Series Catalog

Application Information:

  • Voltage Tolerance: AC Operation: +10/-15% of nominal at 50/60 Hz.
  • Load (Burden): 3 VA
  • Indicator LEDs:
    • Seal Leak: Green ON with input voltage applied; no seal leak and relay energized; Red ON when seal leak detected and relay de-energized
    • Temperature: Green ON with input voltage applied, normal temperature condition and relay energized; Red ON when over temperature detected and relay de-energized
  • Probe Voltage: 5V DC Pulsed
  • Response Time: Pick-up & Drop-out: 1 Second
  • Output Contacts: 7A @ 240V AC/7A @ 28V DC, 1/4HP @ 120V AC (N.O.)
  • Life: Mechanical: 10,000,000 operations; Full Load: 100,000 operations
  • Temperature: -28o to 65o C (-18o to 149o F)

Approvals:

Dimensions: